Handheld veterinary urine analyzer — 11-parameter dipstick reader with LCD result display and touch controls, eliminates visual color-match errors.
Product Overview
IWA-UR10 is a handheld 11-parameter veterinary urine analyzer. Reads standard urine reagent strips electronically — eliminating visual color-matching variability between clinicians. Standard 11-parameter panel covers LEU, BLD, NIT, KET, UBG, BIL, PRO, GLU, pH, VC and SG. LCD result display, touch buttons, and on-board memory for case archiving.
Key Features
- Veterinary point-of-care (POCT) workflow — bedside / chairside operation
- Single-use consumables prevent cross-contamination between patients
- 11-parameter standard urinalysis panel
- Electronic strip reading — eliminates visual color-match variability
- LCD result display with all parameters at a glance
- Touch button operation
- On-board memory for case record archiving
- Bluetooth-ready (per configuration) for data export
- Battery-powered handheld form for in-clinic use
Technical Specifications
| Parameters | 11 (LEU, BLD, NIT, KET, UBG, BIL, PRO, GLU, pH, VC, SG) |
| Strip type | Standard 11-parameter urine reagent strip |
| Display | LCD |
| Operation | Touch button |
| Form factor | Handheld |
Clinical Applications
- Routine veterinary urinalysis (UTI, diabetes, kidney disease screening)
- Pre-anesthesia urinalysis
- Hospitalization patient daily urine monitoring
- Mobile and field clinic urinalysis
Package Contents
- IWA-UR10 handheld analyzer × 1
- Sample 11-parameter urine reagent strips
- Battery (pre-installed)
- Operating manual
Why Choose IWA-UR10
- Veterinary POCT workflow — fast in-clinic / chairside / bedside results
- Designed for canine, feline, equine, bovine and other companion / production species
- Single-use consumable workflow — no patient cross-contamination
- Compact form factor — minimal footprint
FAQ
Which species is the device validated for? Designed for veterinary POCT in canine, feline, equine, bovine and other companion / production animal species. Cross-check species-specific reference ranges in your literature when interpreting results.
How is the device cleaned between patients? Wipe the housing with veterinary-grade disinfectant wipes. The sample inlet area is wiped clean and single-use test strips / cartridges / capillaries prevent cross-contamination.
What is the calibration requirement? Each consumable lot is factory-calibrated. The device reads the lot calibration code automatically (where supported) or requires a one-time code entry per new lot.