iPet-400 Veterinary DR X-ray Imaging System

Original price was: $30,000.00.Current price is: $24,000.00.

★ Canon E7239X X-ray tube · 32 kW high-frequency generator
★ 17×17″ CsI flat-panel detector, 16-bit, 3.6 LP/mm
★ 1-second image acquisition · iVetXray + MiniPACS workflow
★ 4-way floating table · 2-year warranty

SKU: IWA-DR01 Categories: ,

Veterinary digital radiography system built around a 32 kW high-frequency generator and 17×17″ flat-panel detector for daily small-animal practice.

Product Overview

iPet-400 veterinary DR X-ray imaging system

IWA-DR01 iPet-400 Veterinary DR X-ray Imaging System is the classical-configuration entry to the IWA small-animal DR line. The system pairs a 32 kW high-frequency generator and a Canon E7239X rotating-anode X-ray tube with a 43×43 cm caesium-iodide flat-panel detector and the iVetXray workstation, delivering one-second image acquisition for routine canine, feline, and exotic patients.

Designed as a fixed-room installation, IWA-DR01 covers the full range of general radiography — thorax, abdomen, skeletal, dental — in a configuration optimised for clinics that need reliable, high-throughput static imaging without the cost of dynamic fluoroscopy.

Key Features

  • 32 kW high-frequency generator covering 40–150 kV / 10–400 mA / 1–10000 ms for full small-animal anatomy.
  • Canon E7239X rotating-anode X-ray tube with dual focus 1.0 / 2.0 mm and 140 kHU anode heat capacity for sustained throughput.
  • 17×17″ CsI flat-panel detector, 3072×3072 matrix, 139 µm pitch, 16-bit A/D, 3.6 LP/mm spatial resolution.
  • One-second image acquisition via GigE interface — preview on the workstation in under a second after exposure.
  • iVetXray acquisition software with built-in veterinary measurement tools (VHS, TPLO, HIP, TTA).
  • Dual-display workstation: 23.8″ diagnostic monitor plus 21.5″ tableside touchscreen.
  • Veterinary patient table 1400×700 mm, phenolic-resin top, ±75 mm longitudinal and ±200 mm lateral float.
  • LED collimator with 1.0 mm Al inherent filtration at 75 kV; manual field setting.
  • DICOM 3.0 compliant workstation with MiniPACS image viewer, print, and PACS integration.

Product Gallery

Detail views of the gantry, X-ray tube head, four-way floating patient table, LED collimator, and operator workstation.

iPet-400 gantry and tube column
iPet-400 X-ray tube head and high-voltage assembly
iPet-400 four-way floating patient table
iPet-400 LED collimator and field-sizing controls
iPet-400 operator workstation and tableside touchscreen

Technical Specifications

High-voltage generator

Output power 32 kW
kV range 40 – 150 kV
mA range 10 – 400 mA
mAs range 0.1 – 100 mAs
Exposure time 1 – 10000 ms
Power input Single phase, 110/220 VAC ±10%

X-ray tube (Canon E7239X)

Max voltage 125 kV
Focal spot 1.0 / 2.0 mm (dual)
Anode input power 21 kW (small) / 42.5 kW (large)
Anode heat capacity 140 kHU

Flat-panel detector

Technology a-Si TFT, CsI scintillator
Image size 43 × 43 cm (17×17″)
Pixel matrix 3072 × 3072
Pixel pitch 139 µm
A/D conversion 16 bit
Spatial resolution 3.6 LP/mm
Image acquisition 1 s
Data interface GigE
Min. detectable dose (RQA5) 14 nGy
Sealing IP65

Patient table & collimator

Table size 1400 × 700 mm, phenolic resin top
Table movement X: 75 ±10 mm, Y: 200 ±10 mm
Collimator light source LED
Filter 1.0 mm Al at 75 kV

Workstation

Software iVetXray (acquisition) + MiniPACS (viewer)
Display 23.8″ diagnostic monitor + 21.5″ tableside touchscreen
OS Windows 10
Storage 256 GB SSD + 1 TB HDD

Clinical Applications

  • Canine and feline thoracic and abdominal radiography
  • Orthopaedic surveys including hip dysplasia and TPLO / TTA planning
  • Dental and skull views
  • Exotic and small-mammal general radiography
  • Routine pre-anaesthetic and post-operative imaging

Clinical Imaging Samples

Representative radiographs captured on iPet-400 across companion-animal and exotic species, illustrating image quality across body sizes and tissue contrast.

Feline pregnancy radiograph, lateral view
Feline pregnancy — lateral
Feline pregnancy radiograph, ventrodorsal view
Feline pregnancy — VD
Snake whole-body radiograph
Ophidian — whole body
Chelonian radiograph
Chelonian
Avian radiograph
Avian

Workflow & Installation

Single-phase 110/220 VAC power, no dedicated three-phase supply required. Installation footprint accommodates the 1.4 m patient table with overhead tube column. Operating environment: 5–35 °C, 10–75 % RH. Engineer-led installation and on-site operator training are included.

iPet-400 installation and operator training walkthrough (English narration, 6 min)

Package Contents

  • High-voltage generator + control box
  • X-ray tube assembly (Canon E7239X) + high-voltage cables
  • 17×17″ CsI flat-panel detector + tethered power / data adapter
  • LED collimator
  • Patient table (1400×700 mm) with four-way floating top
  • iVetXray workstation: 23.8″ display, 21.5″ touchscreen, PC, software dongle
  • V-shape positioning set (1 large + 1 small)
  • Lead protection set: gown, hat, scarf, glasses, gloves
  • Foot switch, remote control, network cable (10 m)

Downloads

Why Choose IWA-DR01

  • Workflow efficiency — 1-second acquisition with one-touch APR presets keeps room turnover high.
  • Clinical accuracy — 16-bit CsI detector and Canon tube deliver consistent exposure for diagnostic-quality images.
  • Practice economics — entry-level configuration with proven core components keeps installation and service cost predictable.

Warranty & Support

Two-year warranty covering hardware and software. Extended-warranty service is available; spare-parts price list is published for predictable maintenance budgeting. Engineer-led on-site installation and operator training included.

FAQ

Q: Does the system require three-phase power?
No. IWA-DR01 runs on single-phase 110/220 VAC.

Q: Is fluoroscopy supported?
No. IWA-DR01 is a static DR system. For dynamic fluoroscopy, see IWA-DR04 (iSmart-32) or IWA-DR05 (iSmart-32 Pro).

Q: Is the detector wireless?
No. The standard 17×17″ detector is tethered. A wireless detector is available with the IWA-DR02 (iPet-400 Pro) configuration.

Q: What PACS / DICOM standards are supported?
The workstation is DICOM 3.0 compliant for Store, Print, and Worklist with most third-party PACS.

Q: What patient size is supported?
The 1400×700 mm table top accommodates canine, feline, and exotic small-animal patients up to typical large-breed dogs.