iPet-X Veterinary High-Frequency X-ray System

Contact for price

★ Replacement X-ray unit for practices with an ageing or failed machine
★ 32 kW high-frequency generator + Canon E7239X rotating-anode tube
★ 1400 × 700 mm four-way floating table, 200 kg load rating
★ No detector or workstation included — image receptor provided by the user

SKU: IPET-X Categories: ,

The iPet-400AI X-ray platform without the detector and workstation — a direct replacement for an ageing or failed veterinary X-ray unit.

Product Overview

iPet-X veterinary high-frequency X-ray system — full system view

iPet-X is the X-ray unit of the iPet-400AI platform. It keeps the 32 kW high-frequency generator, Canon E7239X rotating-anode tube, LED collimator, 1400 × 700 mm four-way floating table and fixed tube column, and removes the flat-panel detector, acquisition workstation and imaging software.

It is built for practices whose X-ray machine is ageing or out of service and needs replacing. Image receptor equipment is not included; it is provided by the user and is outside the scope of supply.

Key Features

  • 32 kW high-frequency generator — 40 – 125 kV, 10 – 400 mA, 1 – 10000 ms; kV-mA-ms and kV-mAs exposure techniques.
  • Canon E7239X rotating-anode tube — 1.0 / 2.0 mm dual focal spot, 140 kHU anode heat capacity.
  • Four-way floating table — 1400 × 700 mm phenolic resin top, 200 kg load rating, foot-pedal release for single-handed positioning.
  • LED collimator — 43 × 43 cm light field at 1 m SID, 1.0 mm Al inherent filtration at 75 kV.
  • Separate exposure control panel — kV, mA, ms / mAs and focal spot are set on a dedicated control panel.
  • Same platform as iPet-400AI — the same generator, tube, collimator and table as the AI-DR system.


Product Gallery

Detail views of the components iPet-X shares with the iPet-400AI platform.

iPet-X tube column with body-size scale
Tube column with body-size scale
iPet-X X-ray tube head and high-voltage cable assembly
Tube head and high-voltage assembly
iPet-X four-way floating table mechanism
Four-way floating table mechanism
iPet-X stainless-steel table edging detail
Stainless-steel table edging
iPet-X tube-to-arm mounting structure
Tube-to-arm mounting structure

System Specifications

High-voltage generator 32 kW high-frequency (veterinary), single phase 110/220 VAC
kV range 40 – 125 kV
mA range 10 – 400 mA
Exposure time 1 – 10000 ms
Exposure technique kV-mA-ms / kV-mAs
X-ray tube Canon E7239X rotating anode
Tube max voltage 125 kV
Focal spot 1.0 / 2.0 mm (dual)
Anode input power 21 kW (small focus) / 42.5 kW (large focus), 0.1 s
Anode heat capacity 140 kHU
Patient table 1400 × 700 mm, phenolic resin top, four-way float (X 75 ±10 mm / Y 200 ±10 mm)
Table height / load rating 780 mm / 200 kg
Column height / SID ≤ 2000 mm / ≥ 1000 mm
Collimator LED light source, 1.0 mm Al filtration at 75 kV, 43 × 43 cm light field at 1 m SID
Exposure control Separate control panel; two-stage hand switch and foot switch
Power supply Single-phase 220 V ±10 %, 50 Hz, protective earth required; current rating [TBC]
Overall dimensions / weight [TBC]
Operating environment 10 – 38 °C, 20 – 75 % RH, 62 – 106 kPa

Image Receptor

iPet-X does not include image receptor equipment. The receptor is provided by the user and is outside the scope of supply.

Clinical Applications

Replacement of an ageing or failed X-ray unit, used with the practice’s own image receptor. General canine and feline radiography — orthopaedic, thoracic and abdominal studies, pre-anaesthetic evaluation and post-operative rechecks — and routine imaging of small and medium exotic species.

For an integrated digital system, see iPet-400AI. For dynamic studies (barium swallow, airway evaluation), see the iSmart-32Pro dynamic DR system.

Workflow & Installation

  • Exposure control — kV, mA, ms / mAs and focal spot are set on a separate control panel; exposure is triggered with the two-stage hand switch or the foot switch.
  • Exposure charts — iPet-X has no body-size automatic exposure or protocol library. Build an exposure chart from the previous unit’s settings and test exposures, recorded against SID and receptor type.
  • Image receptor — not included; provided by the user and outside the scope of supply.
  • Power — single-phase 220 V mains with protective earth; no three-phase supply required.
  • Installation — the room must accommodate the 1.4 m table and fixed tube column. Engineer-led installation and operator training are included.

Package Contents

  • 32 kW high-frequency generator + control box
  • Separate exposure control panel + two-stage hand switch
  • X-ray tube assembly (Canon E7239X) + high-voltage cables
  • LED collimator
  • Patient table (1400 × 700 mm) with four-way floating top and fixed tube column
  • Foot switch
  • V-shape positioning set (1 large + 1 small)
  • Lead protection set: gown, hat, scarf, glasses, gloves
  • Power cable, operation manual, certificate of conformity

Flat-panel detector, acquisition workstation and imaging software are not included. Image receptor equipment is provided by the user and is outside the scope of supply.


Downloads

Documentation for iPet-X is available on request.

Why Choose iPet-X

  • Workflow efficiency — replaces the X-ray unit alone, with exposure parameters set on a separate control panel.
  • Clinical accuracy — 32 kW high-frequency output and a Canon rotating-anode tube give consistent exposures across body sizes.
  • Practice economics — no detector or workstation included, so the practice pays only for the X-ray unit.

Warranty & Support

Two-year warranty covering the generator, tube, collimator and table. Extended-warranty service is available. Engineer-led on-site installation and operator training included.

FAQ

Q: Does iPet-X produce digital images on its own?
No. iPet-X is the X-ray unit only. Image receptor equipment is not included; it is provided by the user and is outside the scope of supply.

Q: Where are exposure parameters set?
On a separate control panel: kV, mA, ms or mAs, and focal spot. Exposure is triggered by the hand switch or foot switch.

Q: How does iPet-X differ from iPet-400AI?
Generator, tube, collimator and table are the same. iPet-X has no flat-panel detector, acquisition workstation, imaging software, AI imaging assistant or DICOM functions.

Q: Does the system require three-phase power?
No. Single-phase 220 V mains with protective earth is sufficient.