5.6 kW portable X-ray source with WiFi connectivity, mains powered as standard and available with an optional built-in battery.
Product Overview
The iFlex-5Pro is a combined high-frequency X-ray source for veterinary radiography, with a kV range up to 125 kV, an 80–200 kHz working frequency, WiFi communication and CE certification.
The standard configuration runs on 100–264 VAC mains power for in-clinic use. An optional built-in lithium battery adds a 48 VDC input and provides one day of standby on a full charge, supporting ambulatory and field work.
Key Features
- Mains powered as standard; optional built-in lithium battery for ambulatory and field settings
- Optional battery: one day of standby on a full charge
- CE certified
- Combined high-frequency X-ray source, 80–200 kHz working frequency
- kV range 40–125 kV with ≤3% kV ripple at 100 kV for stable density images
- 5.6 kW maximum / 5.6 kW nominal output, 5–100 mA tube current
- Wide exposure time 1–10000 ms with ±(2%+0.2 ms) accuracy
- 0.6 mm / 1.8 mm dual focal spot, 20 kJ anode heat storage
- Auto-tube calibration and service software support
- WiFi and RS232 dual communication interfaces
- Standard input 100–264 VAC; with optional battery 100–240 VAC / 48 VDC
Technical Specifications
| Maximum Power | 5.6 kW |
| Working Frequency | 80 – 200 kHz |
| Input Voltage (standard) | 100 – 264 VAC, 50/60 Hz ± 1 Hz |
| Input Voltage (with optional battery) | 100 – 240 VAC / 48 VDC, 50/60 Hz ± 1 Hz |
| kV Range | 40 – 125 kV |
| kV Ripple | ≤ 3% @ 100 kV |
| kV Rising Time | ≤ 1 ms @ 100 kV (10%–90%) |
| mA Range | 5 – 100 mA |
| mAs Range (Non-AEC) | 0.1 – 320 mAs |
| Exposure Time | 1 – 10000 ms |
| Focal Spot | 0.6 mm / 1.8 mm (dual) |
| Anode Target Angle | 15° |
| Anode Heat Capacity | 20 kJ |
| Monoblock Thermal Capacity (standard) | 40 kJ |
| Auto-tube Calibration | Yes |
| Communication | WiFi, RS232 |
| Battery | Optional built-in lithium battery; one day of standby on a full charge |
| Hand Switch | Optional |
| Operating Temperature | 0 – 40 °C |
| Cooling System | Natural air cooling |
| Earth Leakage Current | Standard ≤ 5 mA; with optional battery ≤ 1 mA |
| Dimensions (W×D×H) | Standard 383 × 240 × 214 mm; with optional battery 390 × 250 × 200 mm |
| Weight | Standard 14.5 kg ± 0.5 kg; with optional battery 14 kg ± 0.5 kg |
| Certification | CE |
| Warranty | 1 year, hardware & software |
Clinical Applications
- Canine and feline thoracic, abdominal, pelvic, limb and spinal radiography
- Mobile radiography in wards and surgical areas on the optional folding cart
- Field-based equine and large-animal radiography (optional battery)
- Mobile veterinary practice and house-call imaging (optional battery)
- Remote clinic deployments without reliable mains power (optional battery)
- Veterinary teaching and demonstration environments
Package Contents
- 1 × iFlex-5Pro X-ray source (mains powered; battery factory-fitted when ordered)
- 1 × Power cord or adaptor (per configuration); AC/DC adaptor supplied with the optional battery
- 1 × Hand exposure switch (optional remote)
- 1 × User manual
- 1 × CE certificate copy
- 1 × Warranty certificate
- Optional: built-in lithium battery
- Optional: mobile folding cart
- Optional: detector protection case
- Optional: V-shape positioning set
- Optional: lead protective set
Why Choose iFlex-5Pro
- One product for in-clinic and ambulatory work: add the built-in battery only when field imaging is required
- With the optional battery, the 48 VDC input allows operation from external vehicle or generator batteries
- CE certification supports regulatory acceptance in international markets
- Tight kV regulation (≤3% ripple) improves repeatability of paired DR images
- Dual 0.6 mm / 1.8 mm focal spots cover both fine extremity detail and thoracic or abdominal studies
Warranty & Support
1-year manufacturer warranty on hardware and software. Terms for the optional built-in battery are agreed separately as a consumable. Remote diagnostics and spare-part support are provided by our service team.
Frequently Asked Questions
- Is the battery included as standard?
- No. The standard configuration runs on 100–264 VAC mains power. A built-in lithium battery is available as an option and is fitted at the factory when ordered.
- How long does the optional battery last per charge?
- A full charge provides one day of standby. The number of exposures per charge depends on technique settings; charge the unit from mains power overnight.
- Can it run from a vehicle power supply?
- Yes, when the optional battery is fitted. The unit then accepts a 48 VDC input from a vehicle supply or external battery. Confirm any non-original power source with us before use.
- Can it be paired with a wireless detector?
- Yes. The WiFi and RS232 interfaces link the unit to a paired detector and acquisition software; integration is confirmed per proposal.
- What is the maximum output?
- 5.6 kW maximum and nominal power, 40–125 kV and 5–100 mA, with kV-mA-ms or kV-mAs technique selection.













Reviews