Compressor nebulizer delivering 4 µm aerosol to the lower respiratory tract of canine and feline patients.
Product Overview
The VCN2 is a compressor (jet) nebulizer for veterinary respiratory therapy. An oil-free lubricated piston pump drives the nebulizer cup at 60–130 kPa, producing a mist with a mass median diameter of 4 µm ± 25% that reaches the trachea, bronchi, and alveoli.
A maximum nebulization rate of 0.2 mL/min, residual volume of ≤ 1.0 mL, and ≤ 60 dB(A) operating noise suit in-clinic and ward aerosol therapy. Species-appropriate face masks and a grid cooling design support repeated treatment sessions throughout the day.
Key Features
- Fine aerosol: 4 µm ± 25% MMD for deposition in the lower respiratory tract
- Stable, continuous mist output at up to 0.2 mL/min for even dosing
- Oil-free lubricated piston pump — clean compressed air and extended pump service life
- Low noise: ≤ 60 dB(A) to limit patient stress during treatment
- Low residual volume: ≤ 1.0 mL of medication left in the cup
- Compatible with a range of nebulizable medications; no water added to the cup
- Animal face masks in skin-friendly, odor-free material that can be disinfected daily
- Grid cooling design for stable operation across repeated daily sessions
Visual Evidence & Media


Technical Specifications
| Power Supply | AC 220 V, 50 Hz |
| Input Power | ≤ 100 W |
| Maximum Nebulization Rate | 0.2 mL/min |
| Residual Volume | ≤ 1.0 mL |
| Particle Size (MMD) | 4 µm ± 25% |
| Output Pressure | 60–130 kPa |
| Compressor Free Flow | ≥ 4.5 L/min |
| Noise | ≤ 60 dB(A) |
| Fuse | T2A / 250 V, Φ2 × 10 |
| Ingress Protection | IPX0 |
| Safety Classification | Not for use in the presence of flammable anesthetic gas mixed with air, oxygen, or nitrous oxide |
| Operating Environment | 5 °C–40 °C; RH ≤ 80%; 86–106 kPa |
| Transport & Storage | -40 °C to +55 °C; RH 10%–93%; 70–106 kPa |
| Dimensions | 15 × 15 × 9 cm |
| Weight | Approx. 1250 g (without battery) |
| Packaging | 280 × 175 × 200 mm |
Clinical Applications
- Aerosol therapy for upper and lower respiratory tract disease in canine and feline patients
- Delivery of nebulized bronchodilators, mucolytics, and antimicrobials as prescribed by the clinician
- Airway humidification and supportive respiratory care for hospitalized patients
- Repeated scheduled nebulization sessions in the ward and isolation unit
Workflow & Operating Notes
- Fill the nebulizer cup with the prescribed medication; no water is added to the cup
- Connect the cup to the compressor with the air tube and fit the appropriate face mask
- Run continuously for the treatment session; the grid cooling design supports repeated sessions through the day
- Disinfect the face mask after each patient; the mask material tolerates daily disinfection
- Do not operate in the presence of flammable anesthetic gas mixtures
Package Contents
- 1 × VCN2 compressor nebulizer main unit
- Nebulizer cup and air tubing
- Animal face mask(s)
Downloads & Documentation
Product brochure and user manual are available on request — contact our sales team.
Why Choose the VCN2
- Workflow efficiency: compact 15 × 15 × 9 cm unit sets up in the consult room or ward with a single cup-and-mask connection
- Clinical accuracy: 4 µm MMD particles and stable output support consistent drug deposition in the lower airways
- Practice economics: ≤ 1.0 mL residual volume reduces medication waste, and the oil-free pump extends service life
Warranty & Support
Warranty terms for the main unit are confirmed at the time of order. Probes, cuffs, cables and other accessories follow standard wear-item terms.
Frequently Asked Questions
- What particle size does the VCN2 produce?
- A mass median diameter of 4 µm ± 25%, suitable for deposition in the trachea, bronchi, and alveoli.
- How fast does it nebulize?
- Up to 0.2 mL/min, with ≤ 1.0 mL residual medication in the cup.
- Which medications can be nebulized?
- The VCN2 is compatible with a variety of nebulizable drugs. Drug selection and dose remain at the clinician’s discretion.
- Can it be used alongside inhalation anesthesia?
- It must not be operated in the presence of flammable anesthetic gas mixed with air, oxygen, or nitrous oxide.
- Is it suitable for repeated daily use?
- Yes. The oil-free piston pump and grid cooling design support continuous operation across repeated treatment sessions.